Electrical Supplies - Recent Questions, Troubleshooting & Support

0helpful
1answer

Why is alarm kohler engine Error code 0094 18

Please see; https://www.fixya.com/support/t25551059-kohler_generator_engine_fault_code_0094
4/20/2024 7:29:35 AM • Kohler... • Answered 2 hours ago
0helpful
1answer

How much wattage does my Coleman Electric central heating furnace with integral limit control 3120-751 use?

The wattage of a furnace can vary based on the model and its specific features. I couldn't access a manual with this information. Perhaps customer support or a dealer can assist with the informaiton. Contact Us ' Support: Get In Touch With Us ' ColemanĀ® Find a Dealer ' HVAC Systems ' ColemanĀ® (colemanac.com) Have the model number handy.
4/19/2024 5:38:48 AM • Coleman... • Answered Yesterday
0helpful
1answer

I have an 1850 Coleman powermate that spews gas from gas cap vent, replaced with new one and still does it. How do I fix?

Troubleshoot this problem: Check Fuel Level: Ensure that the fuel level is not too high. If the tank is filled to the brim, it might cause excess pressure and lead to fuel spewing from the vent. Gas Cap Design: Some gas caps have a metal cone inside to deflect fuel away from the vent hole. Make sure you have the correct gas cap for your generator. The vent hole may not go through the top of the cap but vents under the gasket inside it. Vapor Lock: Coleman customer support suggests that vapor lock could be a possible cause. Try the following steps: Clean the carburetor and its bowl. Disconnect the gas line to ensure it's clear. Use fresh fuel. Inspect the Gas Cap: Double-check that the new gas cap you installed matches the correct part number according to the parts list. Replace the Gas Cap: If all else fails, consider getting a replacement gas cap specifically designed for your Powermate 1850 generator. You can find suitable gas caps online or at authorized dealers. PowerMate Formerly Coleman Gas Caps 4-Cycle - Jacks Small Engines
4/19/2024 5:18:05 AM • Coleman... • Answered Yesterday
0helpful
1answer

Fix overtemp light on in kipor kde6700ta diessel generator

The overtemp light on the Kipor KDE6700TA diesel generator indicates that the engine is overheating. Here are some steps you can take to try to resolve the issue:
  1. Turn off the generator immediately and let it cool down. Check the coolant level in the radiator and top it off if it is low. If the coolant level is consistently low, check for leaks in the coolant system and repair them.
  2. Check the radiator fins for any blockages that may be preventing airflow. Clean the fins using compressed air or a soft brush.
  3. Check the fan belt tension and replace the belt if it is worn or loose. A loose belt can cause the fan to rotate at a slower speed, reducing the cooling capacity of the radiator.
  4. Check the thermostat to ensure that it is functioning correctly. If the thermostat is stuck in the closed position, it can cause the engine to overheat.
  5. Check the water pump to ensure that it is working correctly. A faulty water pump can reduce the flow of coolant through the engine, causing it to overheat.
  6. If you have tried all the above steps and the overtemp light is still on, it may be necessary to replace the thermostat, water pump, or other cooling system components. It's recommended to contact Kipor customer support or a qualified technician for further assistance.
Once you have resolved the issue, start the generator and let it run for a few minutes to ensure that it is operating at the correct temperature. Keep an eye on the overtemp light to ensure that it does not come back on.
4/19/2024 2:03:21 AM • Kipor Electrical... • Answered Yesterday
0helpful
1answer

Manual for scorpion sl2800 generator

Yes
4/9/2024 2:32:16 AM • Electrical... • Answered on Apr 09, 2024
1helpful
2answers

What's the valve specs for McCulloch FR6000MK generator with 11hp 4 stroke?

.010" inlet hot and .012" exhaust hot
4/7/2024 12:18:07 AM • McCulloch... • Answered on Apr 07, 2024
0helpful
2answers

My conlog meter is showing the rfcon error please what do I do

No connecting to your utilty company in South Africa. Just FYI, we are a North American site and my not always have the answer, in this case we do Https://www.facebook.com/ConlogSolutions/posts/im-having-a-rf-con-error-cant-do-anything-on-the-gadget-please-help-on-how-to-re/962048393965724/ Quoting from link above: "Conlog Hi Ola-daniels, Please see below steps to assist with RFCON error : * Press the Back arrow on the keypad - this step is to refresh the UIU ( the device) * Type # 75 # - this is to check the signal strength If it does not go back to the normal display *Type # 80 # - this is to refresh the meter Then lastly you can repair the meter and the UIU by # 36 # The above steps will work better if you are outside the house because the meters uses the radio frequency connection The above error will occur in instances of bad weather conditions or if there is load shedding or power failure If the problem persists after trying the above you may contact the municipality or the service provider."

SOLVED: How do I clear up the rf con error on my meter ...

https://www.fixya.com > ... > The
May 7, 2020 - How do I clear up the rf con error on my meter because I want to ... Https://www.facebook.com/ConlogSolutions/posts/im-having-a-rf-con-error- ... Hi Ola-daniels, Please see below steps to assist with RFCON error : ... shut down the energy alimentation for 2 minute ,but if the defect persist error it show again. SOLVED: Pole meter conlog rf con meter keep on freezing ... Jan. 10, 2017 Meter reading shows rF CON instead of units available - Fixya Jun. 24, 2018 SOLVED: Good day my conlog ip54 elecricity meter showd ... Oct. 6, 2018 SOLVED: Rf con error - Fixya Jun. 20, 2020 More results from www.fixya.com

Please Help With My Conlog Prepaid Meter - Technology ...

https://www.nairaland.com > please-conlog-prepaid-meter
Aug. 6, 2020 - ystar: If the conlog meter is showing rf-Con, it means power supply doesn't reach the meter at all its either Loss of phase from the transformer or a loose contact ... How Do I Load The Activation Token On My Conlog Prepaid ... Mar. 17, 2020 I Need A Technician To Fix This... - Nairaland / General - Nigeria Jul. 22, 2019 I Need Number Codes To Reset Memmcol Prepaid Meter ... Jan. 11, 2019 More results from www.nairaland.com
3/24/2024 3:42:46 AM • Electrical... • Answered on Mar 24, 2024
0helpful
1answer

I'm looking for some schematics for wiring and control board for Schumacher XC103W charger

Some Schumacher manuals have the wiring diagrams in the back but not this one. This page shows their Support address. https://www.manualslib.com/manual/769114/Schumacher-Electric-Xc75.html?page=21#manual Some diagrams here, but yours is electronic. https://www.google.com/search?q=schumacher+xc103w+wiring+diagram ..
3/24/2024 1:19:02 AM • Schumacher... • Answered on Mar 24, 2024
0helpful
1answer

Kipor KDE 12STA - Diesel Generators. L.H Protect light illuminated with emergency stop.

Question edited for clarity. No such word as 'propect'. Normally over speed, over voltage or a voltage leak in the generator windings. Contact the maker. https://www.google.com/search?q=Kipoor+KDE+12STA+-+Diesel+Generators.+L.H+Protect+light ..
3/23/2024 8:04:06 AM • Kipor Electrical... • Answered on Mar 23, 2024
0helpful
1answer

Wiring 3 lights 3 separate switches

Consult a qualified electrician.
3/23/2024 7:13:23 AM • Electrical... • Answered on Mar 23, 2024
0helpful
1answer

Pramac px5000 plug stuck in ac socket

If the plug of your Pramac PX5000 generator gets caught in an AC socket, follow these steps: 1. Turn off the electricity to the socket.2. Wear insulated gloves for safety.3. Gently wiggle the plug while pulling it out.4. Apply a bit of lubricant if needed.5. Use insulated pliers to grip and pull the plug.6. If you cannot take it away, get help from an expert electrician to keep it away from harm or injury.
3/19/2024 1:25:41 PM • Pramac... • Answered on Mar 19, 2024
0helpful
1answer

Generator motor runs fine, not getting electrical

You may have a bad cap or two on the inside
3/11/2024 1:43:36 PM • Coleman... • Answered on Mar 11, 2024
0helpful
1answer

Gentron GG10020 Generator doesn't start news.

No that is definitely not good news is it! All the reasons of what causes the bad news https://www.google.com/search?q=Gentron+GG10020+Generator+doesn%27t+start ..
2/19/2024 12:21:58 AM • Gentron... • Answered on Feb 19, 2024
6helpful
3answers

No electric power generated from my Coleman Powermate Maxa 5000W.

the gensets on coleman generators are definately nothing to brag about but i would start by checking the windings and make sure the brushes have a clean armature to ride on
2/18/2024 6:57:19 PM • Coleman... • Answered on Feb 18, 2024
0helpful
1answer

Steamist Steam Generator. When I start my steam generator it stops at 32 temperature giving double EE error. What should I do?

Question edited for clarity and spelling of the maker. Question moved from Laundry Irons category. I found this On 2021-12-23 by Inspectapedia Com Moderator - Diagnose & Clear an EE error code on some Steam Generators @mike c, Diagnose & Clear an EE error code on some Steam Generators: What are the brand and model of your steam generator? I ask because error codes are not universal across all steam generator brands and models. But on the off chance we can GUESS usefully Your steam generator may be receiving water at an excessive pressure. We've seen this EE error code reported for Happybuy Steam Generators (Amazon): Check the water pressure being delivered to your unit to be sure it's not higher than is permitted by the IO manual or try reducing the supply pressure to 5 psi. Then turn the unit off and drain pressure from the unit. Leave it off for a few minutes or longer. Then return power and water supply - at 5 psi. More here including a link to the maker https://www.google.com/search?q=steamist+steam+generator+ee+error+code ..
2/15/2024 12:29:59 AM • Steamist SM-46... • Answered on Feb 15, 2024
Not finding what you are looking for?
Electrical Supplies Logo

22,741 questions posted

Ask a Question

Usually answered in minutes!

Top Electrical Supplies Experts

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Are you an Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...